Showing Slide 1 of 1
ARLU-210S TO-5 Electromagnetic Relay with Reliability Indicators
ARLU-210S
FEATURES
Solder-sealed, with two sets of switching contacts.
Products Categories
Get A Free Quote
DESCRIPTION
It is used for switching and controlling signals and weak currents, with a load current ranging from low levels up to 1A. It is applied in aerospace computers, communication fields and etc.
SPECIFICATIONS
| Operating Environment Conditions | |||
| Temperature Range | -65℃ to 125℃ | Sinusoidal Vibration | 30g,(10~3000)Hz |
| Relative Humidity | Up to 98%at 40℃ | Random Vibration | 0.4g²/Hz,2391m/s |
| Low Air Pressure | 4.39kPa | Shock | 75g,6ms |
| Acceleration | L LEVEL:50g M LEVEL:100g | ||
| Main Technical Specifications | |||
| Coil Power Consumption | ≤0.5W | Dielectric Strength | At Normal Atmospheric Pressure: 500Vr.m.s.50Hz At Low Air Pressure:125Vr.m.S..50Hz |
| Contact Load and Life Cycle | Resistive,1A,28Vd.c..1x105times Resistive,0.25A,115Va.c.,1x105times Low Level,(10~50)μA,(10~50)mV,1×10=times | Insulation Resistance | At Normal Atmospheric Pressure:≥10000MΩ After High Voltage Test:≥1000MQ |
| Weight | ≤2.55g | ||
| Contact Resistance | lnitial Values100mO After Life Test≤200mΩ | Sealing Performance | Leakage rate≤10-Pa ·cm³/s |
| Time Parameters | Action Time:≤2ms Release Time:≤1.5ms(with diode≤4ms) | Failure Rate Level | L level (Sub-level 5)or M level (Level 5) |